Blog > Fire Regulations for Student Accommodation Explained

Fire Regulations for Student Accommodation Explained

Fire and Security
Adam Barrett
Written by Adam Barrett Published: 5th March 2025 Last update: 19th May 2026

All types of student accommodation, including privately rented units, dorms, halls, and shared housing, must comply with fire safety regulations.

Although the exact measures required might differ depending on the layout and nature of the building, any landlord or campus providing on-site accommodation must demonstrate that they have complied with the regulations to prevent or mitigate avoidable fire risks.

While student tenants still have a duty of care to follow the fire safety procedures and rules provided, the landlord or person in charge of managing the accommodation is ultimately held responsible for adhering to the relevant standards.

Clearway’s fire safety specialists have put together this brief guide to explain, step by step, all you need to know about the current fire regulations for student accommodation.

Contents

    Key takeaways

    • Student accommodation landlords or building managers are responsible for complying with all relevant standards and legislation, including the Fire Safety Act 2021 and the Regulatory Reform (Fire Safety) Order 2005.
    • As a minimum, landlords or management must ensure that every floor has smoke alarms, up-to-standard fire doors, fire extinguishing facilities such as extinguishers and blankets, and fire alarm systems.
    • Alongside fire safety equipment, responsible parties must conduct regular fire risk assessments, make changes where needed or when a new risk is identified, and communicate the fire safety procedures in place to all student residents.
    • Accommodation over 11 metres is subject to additional rules around verifying the safety of building materials, providing information and reporting to the local fire service, and conducting more regular inspections.
    student housing fire

    The Basics of Fire Safety Obligations for Student Landlords and Dorm Managers

    Many of the current standards have been in place for some time. They focus on minimising the potential for an appliance to malfunction, fitting adequate smoke or fire detection systems, installing functional carbon monoxide detectors, and providing appropriate fire extinguishers.

    However, much of the confusion about changing responsibilities arises from the contrasts in rules depending on whether a student accommodation building is new or long-standing, a residential or purpose-built property, a single or double-storey home, or a high-rise building.

    The following rules typically apply to any student accommodation on a university campus or a private rental property elsewhere.

    Fire Safety Facilities

    Student accommodation buildings should have at least one fire alarm on every floor of the property, with a policy in place to test alarms and call points regularly and maintain them to ensure they are in good working order.

    Fire doors certified to the appropriate standards should be fitted where required and inspected to ensure there is no damage and that doors are not being propped open.

    Fire extinguishers or blankets should be installed next to potential points of ignition or higher-risk areas, such as in kitchens, and CO2 alarms should be installed in any space with a gas appliance.

    Maintaining and Testing Appliances

    Furnishings and furniture provided by the landlord or university must meet fire safety standards and be made from fire-resistant materials. Any repair work must be completed as quickly as possible and within 28 days at the latest.

    Appliances like TVs, fridges, freezers, and microwaves should be PAT tested and replaced or decommissioned immediately if they fail.

    Landlords and accommodation supervisors should also hold a valid Electrical Installation Condition Report (EICR), which needs to be updated every five years and confirms that the building’s electrics are safe.

    Adam Barrett

    Adam Barrett

    Managing Director, Clearway Technology Clearway

    Adam Barrett
    Student accommodation presents unique fire safety challenges due to high occupancy density and transient populations, which is why we see landlords and universities implementing compartmentation strategies and regular fire door inspections as critical control measures rather than optional extras.

    Get a quote

    • Speak to the experts
    • Get an assessment
    • Get a quote

    Student Communications

    Landlords and responsible parties must communicate a clear fire safety plan and risk assessment process with student residents, including instructions about how they should report maintenance issues or faults and raise the alarm in an emergency.

    They must ensure that students know how to evacuate the building, where the escape routes are, and where fire alarm call points are, eliminating the risk of hesitation or a failure to evacuate at the first signs of a fire.

    Do fire alarms need servicing - Clearway

    Understanding Student Accommodation Fire Safety Legislation Reforms

    Recent changes following the Grenfell Tower tragedy and the student accommodation fire at The Cube in Bolton have introduced new rules. However, these apply primarily or only to multi-occupant or multi-storey residential student housing.

    While these are partly intended to clarify and strengthen fire safety regulations, they’ve also prompted concern from accommodation management and landlords who are unsure whether their current policies are sufficient or whether they need to take additional steps.

    The existing legislation, the Regulatory Reform (Fire Safety) Order 2005, remains in place, but the Fire Safety Act 2021 has augmented it.

    This includes new rules and revisions, including the requirement to share fire reporting procedures and instructions with all new residents as soon as possible when they move in and fire safety rules around the use of fire doors.

    New Fire Safety Regulations for Student Accommodation Over Eleven Metres in Height

    The following requirements apply specifically to multi-storey buildings, and in particular, student accommodation that is 11 metres or more in height:

    • Fire safety doors must be included within fire risk assessments, ensuring these are self-closing, in good repair, and checked regularly at least every 12 months.
    • Checks on fire doors in communal areas should now be performed at least every three months, alongside checks of frames, glazing, and smoke seals.
    • Landlords or managers must add clear wayfinding signage for evacuations and to assist emergency services, including for buildings constructed before November 2020, when this was not a Building Regulations requirement.
    • There must be a secure information box with a copy of floor plans, contact details for the responsible person, and any other individuals with the authority to access the building on their behalf.

    Importantly, this new regulation requires landlords or student accommodation providers to record the design and materials used within the external walls and share this information with the local fire and rescue service.

    If there are any fire safety risks linked to the cladding, insulation, building materials, structural integrity, and any fixtures or attachments, the responsible person must detail the steps they have taken to mitigate risks and report this to the local fire department.

    Clearway Fire Roll Call Solution

    How to Ensure Your Student Accommodation is Fully Compliant With All Fire Regulations

    We appreciate that there are multiple rules, expectations, obligations, and requirements. It can be difficult to navigate or identify where current fire safety provisions need to be revised or updated to remain fully up to speed.

    If you have any concerns about your approach to fire safety in student accommodation, how the new regulations might impact you, or whether you need to make swift changes, please contact our experienced fire safety consultants, who will be happy to advise. We offer a wide range of fire and security systems for student accommodation.

    Should you find that changes are necessary, we can also share insights into the best solutions in terms of quick installation times, full compliance with the standards, and cost-efficiency, ensuring you take a proactive stance on fire safety that more than satisfies your obligations.

    Adam Barrett

    Written by Adam Barrett

    Managing Director, Clearway Technology

    Adam began his career as an apprentice electrician, developing a strong technical foundation and practical understanding of electrical systems before progressing into engineering roles within the fire and security sector. This hands-on experience has shaped his approach to leadership, with a deep appreciation for technical excellence, compliance, and the realities of delivery on site.

    With over 20 years in the UK fire and security industry, he has built his career on delivering safe, compliant, and technically robust solutions, while developing strong client relationships and high-performing teams.

    As Managing Director, Adam leads the strategic and operational performance of Clearway Technology, with a focus on sustainable growth, service excellence, and consistent delivery. He works closely with engineering, compliance, and service teams to ensure projects and maintenance contracts are delivered right first time, aligned with customer requirements, regulatory standards, and long-term system performance.

    His experience spans the delivery and management of integrated fire and security solutions, including CCTV, access control, intruder alarms, remote monitoring, and wider electronic security infrastructure. He has a particular interest in system integration, compliance, cyber-aware security design, and data-led service delivery in creating resilient, future-ready environments.

    Adam believes strong leadership is about clear direction, accountability, and empowering people to perform at their best, while keeping customer outcomes at the centre of every decision.

    Beyond the boardroom, he plays an active role in helping shape the industry through his positions as:

    • Vice Chairman – BSIA Security Systems Section
    • Council Member – FIA Services Council

    Get a quote

    • Speak to the experts
    • Get an assessment
    • Get a quote

    Are you looking for a job?

    It looks like you’ve submitted your information in the wrong section of our website. No problem—if you’re looking to apply for a job, you can do so by viewing our current vacancies. Click below to find and apply for roles through the proper channel.

    View our current vacancies
    inView Highway Technology tower from Clearway
    Back to top
    Close

    What are you looking for?